Marque
Fluke®

FLUKE-1555 FC,10KV INSULATION TESTER WITH IR 3000FC 1550 CONNECTOR

  • GLD#
    4053158525220196000
  • MFG#
    4977519
Qté min. de commande 1
Description
Testeur disolement fluke, 250/500/1000/2500/5000/10000 vca, 2 mois, 50 à 60 hz fréquence response, résistance de 200 kohm à 2 tohm, résistance de 2 tohms, 5 à 20 % pour 250, 500, 1000, 2500, 5000, 10000v, 0 à 10 % à 1 ma de courant de charge pour le test disolement, +/- (5 % + 2 ua) pour le courant de fuite, +/- (15 % rdg + 0.03 uf) pour la précision de la capacité, écran lcd, cote de sécurité : cat. Iii 1000 v/cat. Iv 600 v, 12 v cc batterie rechargeable au plomb/yuasa np2.Source dalimentation 8-12, interface port pc, ip40 boîtier, dimensions 269 mm l x 277 largeur (mm) x 160 mm h
Spécifications
Plus d'infos
ApplicationFor capturing and trending anomalies for troubleshooting, commissioning and preventative maintenance of insulation resistance
Accuracy5 to 20% for 250, 500, 1000, 2500, 5000, 10000 V, 0 to 10% at 1 mA Load Current for Insulation Test, +/- (5% + 2 uA) for Leakage Current, +/- (15% rdg + 0.03 uF) for Capacitance
Dimensions269 mm L x 277 mm W x 160 mm H
Display TypeLCD
Amperage Rating2 mA
Resistance2 TOhm
Safety RatingCAT III 1000 V/CAT IV 600 V
Voltage Rating250/500/1000/2500/5000/10000 VAC
Power Source12 VDC Lead Acid Rechargeable Battery/Yuasa NP2.8-12
Enclosure TypeIP40
InterfacePC Port
Frequency Response50 to 60 Hz
Resistance Range200 kOhm to 2 TOhm
Caractéristiques
  • Test voltages to up 10 kV and save time by trending on the spot only with Fluke® Connect
  • Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 VAC/ VDC for increased user safety, selectable test voltages in 50 V steps from 250 - 1000 V, and 100 V steps above 1000 V
  • Long battery life gives the user over 750 tests between charges
  • Automatic calculation of dielectric absorption (DAR) and polarization index (PI) with no additional setup
  • Ramp function for breakdown testing
  • Timer settings up to 99 minutes for timed tests
  • Guard system eliminates the effect of surface leakage current on high resistance measurements
  • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
  • 75 x 105 mm LCD, Digital LCD/analog display
  • 2 deg pollution, -20 to 50 deg C temperature rating, IP rating IP40
Guides & Manuels
1726092314_IDW_DOCUMENT_320d00d413807b6d3c564fc65c36bf2d79d12a4c99684f89db80bb6ddf92da21.pdf

IDW_DOCUMENT_320d00d413807b6d3c564fc65c36bf2d79d12a4c99684f89db80bb6ddf92da21.pdf

Télécharger
1726092313_IDW_DOCUMENT_46666252c3f9fdf4cfaa53846c0258ce7937351d2e976fd9e30f9754cf28462e.pdf

IDW_DOCUMENT_46666252c3f9fdf4cfaa53846c0258ce7937351d2e976fd9e30f9754cf28462e.pdf

Télécharger

AVANTAGES POUR PROFESSIONNELS

Connecte-toi ou crée un compte pour professionnels, afin d’obtenir avantages et prix exclusifs!

avantages