Brand
Fluke®
FLUKE-1555 FC,10KV INSULATION TESTER WITH IR 3000FC 1550 CONNECTOR
- GLD# 4053158525220196000
- MFG# 4977519
Min. Order Qty 1
Description
Testeur disolement fluke, 250/500/1000/2500/5000/10000 vca, 2 mois, 50 à 60 hz fréquence response, résistance de 200 kohm à 2 tohm, résistance de 2 tohms, 5 à 20 % pour 250, 500, 1000, 2500, 5000, 10000v, 0 à 10 % à 1 ma de courant de charge pour le test disolement, +/- (5 % + 2 ua) pour le courant de fuite, +/- (15 % rdg + 0.03 uf) pour la précision de la capacité, écran lcd, cote de sécurité : cat. Iii 1000 v/cat. Iv 600 v, 12 v cc batterie rechargeable au plomb/yuasa np2.Source dalimentation 8-12, interface port pc, ip40 boîtier, dimensions 269 mm l x 277 largeur (mm) x 160 mm h
Specifications
Application | For capturing and trending anomalies for troubleshooting, commissioning and preventative maintenance of insulation resistance |
---|---|
Accuracy | 5 to 20% for 250, 500, 1000, 2500, 5000, 10000 V, 0 to 10% at 1 mA Load Current for Insulation Test, +/- (5% + 2 uA) for Leakage Current, +/- (15% rdg + 0.03 uF) for Capacitance |
Dimensions | 269 mm L x 277 mm W x 160 mm H |
Display Type | LCD |
Amperage Rating | 2 mA |
Resistance | 2 TOhm |
Safety Rating | CAT III 1000 V/CAT IV 600 V |
Voltage Rating | 250/500/1000/2500/5000/10000 VAC |
Power Source | 12 VDC Lead Acid Rechargeable Battery/Yuasa NP2.8-12 |
Enclosure Type | IP40 |
Interface | PC Port |
Frequency Response | 50 to 60 Hz |
Resistance Range | 200 kOhm to 2 TOhm |
Features
- Test voltages to up 10 kV and save time by trending on the spot only with Fluke® Connect
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 VAC/ VDC for increased user safety, selectable test voltages in 50 V steps from 250 - 1000 V, and 100 V steps above 1000 V
- Long battery life gives the user over 750 tests between charges
- Automatic calculation of dielectric absorption (DAR) and polarization index (PI) with no additional setup
- Ramp function for breakdown testing
- Timer settings up to 99 minutes for timed tests
- Guard system eliminates the effect of surface leakage current on high resistance measurements
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- 75 x 105 mm LCD, Digital LCD/analog display
- 2 deg pollution, -20 to 50 deg C temperature rating, IP rating IP40
BENEFITS FOR PROFESSIONALS
Log in or create a professional account to get exclusive benefits and prices!